HOME    SEARCH    ABOUT US    CONTACT US    HELP   
           
Rule: 4.12.723 Prev     Up     Next    
Rule Title: REQUIREMENT OF CONSTRUCTION AND ORIGINAL TEST OF CONTAINERS
Add to My Favorites
Add to Favorites
Department: AGRICULTURE, DEPARTMENT OF
Chapter: AGRICULTURAL SCIENCES DIVISION
Subchapter: Anhydrous Ammonia Rules
 
Latest version of the adopted rule presented in Administrative Rules of Montana (ARM):

Printer Friendly Version

4.12.723    REQUIREMENT OF CONSTRUCTION AND ORIGINAL TEST OF CONTAINERS

(1)  Containers shall be constructed of a material suitable for use with nitrogen fertilizer solutions.

(2)  Nitrogen fertilizer solution containers shall be designed to withstand at least the maximum pressure to which they may be subjected.

(3)  Containers in excess of 3,000 gallons and designed for 15 psig or greater shall be constructed in accordance with the code.

(4)  Pressure-vented containers not covered by the code shall be tested by the manufacturer at one and one-half (1-1/2)  times the design working pressure.

(5)  Nitrogen fertilizer solution containers of 3,000-gallon capacity or less shall be clearly and permanently labeled as follows:

(a)  name and location of manufacturer.

(b)  design pressure (if pressure vented)  .

(6)  nitrogen fertilizer solution containers in excess of 3,000 gallons shall be clearly and permanently labeled as follows:

(a)  name and location of manufacturer;

(b)  design pressure (if pressure vented)  ;

(c)  serial number;

(d)  nominal water capacity in U.S. gallons;

(e)  year of manufacture.

History: Sec. 80-10-503, MCA; IMP, Sec. 80-10-503, MCA; NEW, 1986 MAR p. 1820, Eff. 10/31/86.


 

 
MAR Notices Effective From Effective To History Notes
10/31/1986 Current History: Sec. 80-10-503, MCA; IMP, Sec. 80-10-503, MCA; NEW, 1986 MAR p. 1820, Eff. 10/31/86.
Home  |   Search  |   About Us  |   Contact Us  |   Help  |   Disclaimer  |   Privacy & Security