HOME    SEARCH    ABOUT US    CONTACT US    HELP   
           
Rule: 4.12.715 Prev     Up     Next    
Rule Title: LIQUID LEVEL GAUGING DEVICES
Add to My Favorites
Add to Favorites
Department: AGRICULTURE, DEPARTMENT OF
Chapter: AGRICULTURAL SCIENCES DIVISION
Subchapter: Anhydrous Ammonia Rules
 
Latest version of the adopted rule presented in Administrative Rules of Montana (ARM):

Printer Friendly Version

4.12.715    LIQUID LEVEL GAUGING DEVICES

(1)  Each container, except containers filled by weight, shall be equipped with a liquid level gauging device of approved design.

(2)  All gauging devices shall be arranged so that the maximum liquid level to which the container may be filled is readily determined.

(3)  Gauging devices that require bleeding of the product to the atmosphere, such as the rotary tube, fixed tube and slip tube, shall be so designed that the bleed valve maximum opening is not larger than a No. 54 drill size, unless the device is equipped with an excess flow valve.

(4)  Gauging devices shall have a design working pressure at least equal to the design pressure of the storage tank on which they are used.

(5)  Fixed liquid level gauges shall be so designed that the maximum volume of the container filled by liquid shall not exceed 85 percent of its water capacity. The coupling into which the fixed liquid level gauge is threaded must be placed at the 85 percent level of the container. If located elsewhere, the dip tube of this gauge must be installed in such a manner that it cannot be readily removed. This does not apply to refrigerated storage of anhydrous ammonia.

History: Sec. 80-10-503, MCA; IMP, Sec. 80-10-503, MCA; NEW, 1986 MAR p. 1820, Eff. 10/31/86.


 

 
MAR Notices Effective From Effective To History Notes
10/31/1986 Current History: Sec. 80-10-503, MCA; IMP, Sec. 80-10-503, MCA; NEW, 1986 MAR p. 1820, Eff. 10/31/86.
Home  |   Search  |   About Us  |   Contact Us  |   Help  |   Disclaimer  |   Privacy & Security